BV70 Differential Control Valve
The Brodie BV70 differential control valve is a normally closed, regulating or positioning type valve designed for applications requiring valve closure on decreasing pressure differential such as pump differential pressure control and vapor pressure control for products with high flash points. The valve does not require an outside power source to operate.
A controlled pressure differential is maintained within +/-2% regardless of variations in upstream or downstream pressure.
Brodie Valve Assembly
Brodie Valve Disassembly
BV70 Differential Control Valve
Valve Size | 2″ | 3″ | 4″ | 6″ | 8″ | 12″ | ||
Dimensions | 150 # | Inches | 10¼ | 11 | 13 | 17 | 22½ | CF |
[flange to flange] | MM | 260 | 279 | 330 | 432 | 571 | CF | |
Dimensions | 300 # | Inches | 13⅛ | 14½ | 17⅞ | 23½ | CF | |
[flange to flange] | MM | 333 | 368 | 454 | 597 | CF | ||
Capacity | CV-GPM | 71 | 187 | 237 | 590 | 1178 | CF | |
Pressure | 150 # | SEP | SEP | SEP | CRN, PED | CRN, PED | CF | |
Approvals | 300 # | PED | PED | PED | CF |
CHECK VALVE FUNCTIONALITY
The valve piston spring, biased to the closed position, has equal front and rear surface areas. This means that every Brodie Model BV valve has check valve functionality, with bubble-tight shut-off – no additional system check valve is required to prevent reverse flow. The valve will only open when upstream pressure is sufficient to overcome spring force.
BRODIE VS DIAPHRAGM VALVES
There are many advantages in using piston-operated control valves as opposed to diaphragm-operated valves, including:
- High flow capacity – lower pressure drop
- Optimum control at low flow gives better batching control
- Simple O-ring sealing – no special diaphragms
- Alternative O-rings easily obtainable per product specifications
Designed to meet the challenges for today’s petroleum and environmental needs, Brodie’s positive sealing and linear action control valves provide uniform speed of response and leak-proof performance.
REDUCED COST OF OWNERSHIP
- Long service life, only one moving part
- Cylinder can be removed without removing body from the line
- Cylinder assemblies available as replacement kits
SECURITY & CONTROL
- Automatic shutoff for emergency protection
- Pressure monitoring at all times
UNIFORM SPEED OF RESPONSE
Flow modulation avoids delayed response and valve slam.
- Pilot operated
- Positive Sealing/Zero Leakage
- Modular construction/easy inline service
- Adjustable opening and closing speeds – prevents damaging shock pressure
- Linear action control for uniform fast speed of control
- Simple design without diaphragms
- Common valve body and internal mechanism simplifies spare parts inventory
- Multiple control functions can be performed with one valve